Hardness Testers
HMAS-C5/10/30/50SZA Automatic Vickers Hardness Measurement & Analysis System
Model HMAS-C5/10/30/50SZA · MICROCRE
In one sentence: for the your team project we recommend the HMAS-C5/10/30/50SZA, delivered as main unit + standard accessories + first training, 15–30 working days for standard configuration.
Theoretical Hardness Range8‑6000HV
ModelHMAS-C5/10/30/50SZA
CategoryHardness Testers
Standard lead time15–30 working days
The short version · Three things to know before the datasheet
What it doesFor measurement and inspection of Hardness Testers, producing traceable records instead of visual checks and manual calculation.
Who it fitsIncoming inspection, lab sampling, process validation and final inspection — the larger the batch and the tighter the tolerance, the bigger the gain.
Not the right fit ifIf you only need a one-off rough check, or your parts exceed this model’s range — in both cases we will propose a cheaper route.
| Customer | — |
Contact | — |
| Tel | — |
Project | — |
| Qty | 1 |
Requirements | Configured around your samples and test items, meeting repeatability and data-traceability requirements for batch inspection. |
In this proposal
P2 Requirement & system layout
P3 Specifications, explained
P4 Scope of supply & workflow
P5 Delivery, service & commercial
· Standards and signature page
About us
Founded in 2005, Shanghai Microcre Optics-Mech Tech Co., Ltd. designs and manufactures material testing and dimensional metrology instruments: hardness testers, metallographic preparation, autocollimators, testing machines and extreme-environment systems across nine product lines with 1,000+ models. National High-Tech Enterprise and Specialised & Innovative SME, ISO 9001:2015 certified, with 100+ software copyrights and 100+ intellectual property rights.
Each model is available in a standard and a premium build; one-year warranty with seven regional service centres.
SHANGHAI MICROCRE OPTICS-MECH TECH CO.,LTD · 400-8127-833 · shanghai@yr17.netYR-P261113-1030
SHANGHAI MICROCRE OPTICS-MECH TECH CO.,LTDTECHNICAL PROPOSAL
HMAS-C5/10/30/50SZA
2026-11-13
1. Your requirement
The goal is accurate, fast and traceable measurement. This proposal is built around those three: the machine secures accuracy, the accessories secure fixturing and throughput, the software secures traceability.
Taking the HMAS-C5/10/30/50SZA as an example, key figures on the cover and in section 4; if sample size or batch differs from the description, fixtures and range are adjusted at the technical-protocol stage without changing the base model.
2. How the system is built
Measuring capabilityWhat it can measure — the first thing to check against your samples
Optics & imagingObjectives, eyepieces, illumination and field of view
Structure & travelStage, travel, dimensions and weight — siting and fixturing
Loading & controlLoading mode, speed, dwell and software interfaces
Power & environmentPower, consumption and ambient requirements
Accessories & configurationStandard, optional and supplied-with items
Modules listed reflect this model’s actual configuration; an omitted group means it does not apply, not that it was left out.
3. Why this model
- Key figures map directly onto acceptance criteria — no conversion, no derating.
- Each model comes in a premium and a standard build, so budget and accuracy can be discussed separately.
- Factory installation, commissioning and training — producing reports from day one; automation or data interfaces can be added later without replacing the machine.
- A premium build of the same model is available: tighter assembly tolerances, upgraded components and higher-grade factory calibration, suited to metrology institutes and research acceptance.
Before you sign: what the price includes — and what it does not
This section is written before signing so that nothing turns up missing on delivery day. It follows the standard configuration; special requirements can be listed separately in the technical agreement.
Included
- Main unit plus factory standard accessories (see Section 5)
- Factory inspection report, certificate, packing list, operation and maintenance manual
- First installation, commissioning and operation training (remote or on site, travel included)
- One-year warranty on the whole unit; free upgrades within the same software version for life
- Domestic transport and transit insurance (up to unloading at your plant)
Not included (quoted separately)
- Special fixtures, custom tooling and modifications beyond the standard range
- Third-party metrology verification or calibration (if a CNAS certificate is required)
- On-site power modification, foundation, compressed air, temperature and humidity control
- Consumables (indenters, cutting wheels, polishing cloths, reference blocks)
- Out-of-warranty on-site service and spare parts
SHANGHAI MICROCRE OPTICS-MECH TECH CO.,LTD · 400-8127-833 · shanghai@yr17.netYR-P261113-1030
SHANGHAI MICROCRE OPTICS-MECH TECH CO.,LTDTECHNICAL PROPOSAL
HMAS-C5/10/30/50SZA
2026-11-13
4. Specifications
Read the numbers
- Theoretical Hardness Range 8‑6000HVMatch the hardness scale to the drawing: HRC on the drawing means HRC, HV means Vickers. Converted values are indicative only.
| 试台尺寸 | 140*180mm,移动范围 50*50mm,最小步距 0.1μm |
|---|
| Model | HMAS‑C5/10/30/50SZA |
|---|
| 软件计算 | Magnification |
|---|
| Dwell Time | 0‑60 秒,最小变动量 1 秒 |
|---|
| Max Specimen Height | 150mm |
|---|
| Power Voltage | AC 220V/50Hz |
|---|
| Overall Dimensions | 220 × 570 × 680mm (L × W × H) |
|---|
| Net Weight | 50.0kg |
|---|
| Measurement & Analysis System | HMAS‑硬度测量分析系统 |
|---|
| Optical Imaging System | 维氏硬度大三通光学成像系统 |
|---|
| Turret Mode | 自动转塔 |
|---|
| Lifting Mechanism | 电动蜗轮蜗杆 |
|---|
| Load Change Mechanism | 砝码加载 |
|---|
| Scale Conversion | HV、HK、HBW、HRA、HRB、HRC、HRD、HRF、HR15N、HR30N、HR45N、HR15T、HR30T、HR45T |
|---|
| 聚焦方式 | Automatic |
|---|
| X/Y stage | Automatic |
|---|
| Z 轴升降 | Automatic |
|---|
| 硬度打压 | PC control |
|---|
| 梯度测试 | 电脑控制(自动连续打压) |
|---|
| 硬度测量 | 连打连测 + 单点自动 / 手动(多测量系统) |
|---|
| 长度测量 | PC automatic |
|---|
| 测试定点 | 自动导航定位 / 路径自动定位 |
|---|
| 基点补偿 | Automatic |
|---|
| 断裂韧性 | 软件计算 |
|---|
| Magnification | (21 寸屏) 10X 物镜,总放大倍数约 320X;20X 物镜,总放大倍数约 650 倍 |
|---|
| Theoretical Hardness Range | 8‑6000HV |
|---|
| Test Force Loading | 全自动(加载 / 保荷 / 卸载) |
|---|
| Executive Standard | GB/T4340 国家标准,ISO6507 质量认证,ASTM 标准 |
|---|
| X‑Y moving stage | 试台尺寸:140*180mm,移动范围 50*50mm,最小步距 0.1μm |
|---|
| Hardness Value Display | (双系统测量) 主机单独测量 / 电脑软件测量分析 |
|---|
| Reading Mode | 目镜按钮读数 / 电脑软件读数 |
|---|
| Calculation Method | 自动计算 |
|---|
| 主机最小检测单位 | 0.12μm (10X 物镜),0.06μm (20X 物镜) |
|---|
| Indenter Center to Wall Distance | 170mm |
|---|
| Gross Weight | 67.0kg |
|---|
Choosing within the series
Only key differences are listed; the highlighted column is the recommended model.
| HMAS-C5/10/30/50SZA | YHRI-45M | HRS-150 |
|---|
| Scale Conversion | HV、HK、HBW、HRA、HRB、HRC、HRD、HRF… | HRA、HRB、HRC、HRD、HRF、HBW、HV、HK… | HRA、HRB、HRC、HRD、HRF、HBW、HV、HK… |
|---|
Three things to check before you compare
- The scale matters more than the number. If the drawing says HRC, measure HRC; if HV, measure Vickers. Converted values are for reference only.
- Range is not accuracy. Range tells you what fits; error and repeatability tell you how accurate it is — read both columns together.
- Acceptance is proven on your samples, not on the brochure. Provide 3–5 real workpieces for an on-site repeatability test; sign once the numbers match.
If you need a benchmark against your current or an imported instrument, we can run the same samples and issue the data.
SHANGHAI MICROCRE OPTICS-MECH TECH CO.,LTD · 400-8127-833 · shanghai@yr17.netYR-P261113-1030
SHANGHAI MICROCRE OPTICS-MECH TECH CO.,LTDTECHNICAL PROPOSAL
HMAS-C5/10/30/50SZA
2026-11-13
5. Scope of supply
- 主机最小检测单位 0.12μm (10X 物镜),0.06μm (20X 物镜)
Consumables and spares are quoted separately by annual usage; for the first order we recommend one set of wear parts to avoid downtime.
6. Inspection workflow
01Sample prep: prepare specimens to the standard, record IDs and ambient conditions
02Fixturing and setup: select the program, confirm load, range and scale
03Measure and verify: consecutive measurements with out-of-tolerance alerts and re-test when needed
04Reporting: export data with calibration status and measurement uncertainty
7. Applicable standards
- GB/T 4340.1 Metallic materials — Vickers hardness test — Part 1: Test method
- ISO 6507-1 Metallic materials — Vickers hardness test
- JJG 151 Verification Regulation of Metallic Vickers Hardness Testers
- GB/T 230.1 Metallic materials — Rockwell hardness test — Part 1: Test method
- GB/T 231.1 Metallic materials — Brinell hardness test — Part 1: Test method
- GB/T 17394.1 Metallic materials — Leeb hardness test — Part 1: Test method
SHANGHAI MICROCRE OPTICS-MECH TECH CO.,LTD · 400-8127-833 · shanghai@yr17.netYR-P261113-1030
SHANGHAI MICROCRE OPTICS-MECH TECH CO.,LTDTECHNICAL PROPOSAL
HMAS-C5/10/30/50SZA
2026-11-13
8. Delivery and implementation
| Stage | Scope | Duration |
| Technical review | Confirm samples, range, fixtures and acceptance criteria; sign the technical protocol | 3–5 days |
| Production and calibration | Assembly, burn-in, factory calibration with data report | 15–30 days |
| Delivery and installation | Crated shipment; unpacking, positioning and commissioning on site | 3–7 days |
| Training and acceptance | Operation and maintenance training; acceptance test with standard samples | 1–2 days |
9. Acceptance and training
- Acceptance basis: the signed technical protocol plus the standards in section 7
- Acceptance samples: please provide 3–5 real workpieces for an on-site repeatability test
- Training goal: the inspector can fixture, measure and issue a report independently
- Documents: manual, conformity certificate, calibration certificate, packing list
10. Service
- One-year machine warranty; replacement for quality issues
- First on-site installation and travel free of charge
- Technical hotline on working days; on-site visit by appointment
- Free lifetime upgrades within the same software version
- Optional automated loading, data interfaces and LIMS/MES integration
- Common spares and consumables kept in stock to shorten downtime
11. Commercial terms
| Price | Quoted on configuration (tax and domestic freight included) |
| Payment | 30% deposit, 70% before shipment |
| Lead time | 15–30 working days for standard configuration |