Carburised gears: disputed case depth
- Part
- 20CrMnTi carburised gear, module 3, 0.6–0.9 mm required
- Problem
- Supplier measured 0.82 mm, OEM re-check 0.61 mm — one batch, two verdicts, line stopped.
- Approach
- HV-1000Z microhardness tester with motorised stage; a point every 0.05 mm per GB/T 9450, depth taken at 550 HV.
- Standard
- GB/T 9450, ISO 2639
- Outcome
- Same machine, same sample, same parameters: spread narrowed to 0.03 mm, closed in three days.